Kod: Zaznacz cały
>>> m122
SENDING:M122
X Y E
Address 0 0 0
Enabled true false false
Set current 800 800 800
RMS current 795 795 795
MAX current 1121 1121 1121
Run current 25/31 25/31 25/31
Hold current 12/31 12/31 12/31
CS actual 12/31 12/31 12/31
PWM scale
vsense 1=.18 1=.18 1=.18
stealthChop true true true
msteps 16 16 16
interp true true true
tstep max max max
PWM thresh.
[mm/s]
OT prewarn false false false
triggered
OTP false false false
pwm scale sum 41 14 14
pwm scale auto 3 0 0
pwm offset auto 95 36 36
pwm grad auto 14 14 14
off time 3 3 4
blank time 24 24 24
hysteresis
-end -1 -1 2
-start 5 5 1
Stallguard thrs 0 0 0
uStep count 808 40 24
DRVSTATUS X Y E
sg_result 400 0 0
stst
olb
ola
s2gb
s2ga
otpw
ot
157C
150C
143C
120C
s2vsa
s2vsb
Driver registers:
X 0xC0:0C:00:00
Y 0xC0:0C:00:00
E 0xC0:0C:00:00
Testing X connection... OK
Testing Y connection... OK
Testing E connection... OK
Wielkie dzięki za pomoc Jarewa !
A radiator jest na płytce, bo drukarka była w zabudowie, gdzie było nawet i 50C, więc wolałem dmuchać na zimnę
Wątpie, żeby grzał się na tyle w normalnych warunkach, żeby trzeba było dawać radiator.