udalo mi sie znalesc pare chwil i przepialem moje corexy z repetiera due3doom na TMC2208/lv8729(na Z i E) na Duet3d wifi.
Mam jakas straszna padake jesli chodzi o jakosc zwyklej kostki, w ogole nie poznaje swojej drukarki
Probowalem juz zmieniac acc/predkosc/mikrokrok w Ztce ale nie pomaga Temperatury tez obnizac/podwyzszac i przemierzylem kroki extrudera ale jest ok
Koledzy, pomozecie?
ponizej config.g
Kod: Zaznacz cały
; Configuration file for Duet WiFi (firmware version 1.20 or newer)
; executed by the firmware on start-up
;
; generated by RepRapFirmware Configuration Tool on Tue Jun 05 2018 23:04:14 GMT+0200 (CEST)
; General preferences
G90 ; Send absolute coordinates...
M83 ; ...but relative extruder moves
M667 S1 ; Select CoreXY mode
; Network
M550 PMorfPrinter ; Set machine name
M552 S1 ; Enable network
M587 S"ssid" P"haslo"; Configure access point. You can delete this line once connected
M586 P0 S1 ; Enable HTTP
M586 P1 S1 ; Enable FTP
M586 P2 S0 ; Disable Telnet
; Drives
M569 P0 S1 ; Drive 0 goes forwards
M569 P1 S1 ; Drive 1 goes forwards
M569 P2 S0 ; Drive 2 goes forwards
M569 P3 S0 ; Drive 3 goes forwards
M350 X128 Y128 Z256 E128 I0 ; Configure microstepping without interpolation
M92 X1280 Y1280 Z2560 E720 ; Set steps per mm
M566 X1200 Y1200 Z12 E120 ; Set maximum instantaneous speed changes (mm/min)
M203 X9000 Y9000 Z360 E3000 ; Set maximum speeds (mm/min)
M201 X1500 Y1500 Z100 E5000 ; Set accelerations (mm/s^2)
M906 X500 Y500 Z800 E600 I100 ; Set motor currents (mA) and motor idle factor in per cent
M84 S30 ; Set idle timeout
; Axis Limits
M208 X0 Y0 Z0 S1 ; Set axis minima
M208 X215 Y184 Z208.3 S0 ; Set axis maxima
; Endstops
M574 X2 Y2 S0 ; Set active low endstops
M574 Z2 S1 ; Set active high endstops
; Z-Probe
;M558 P0 H5 F120 T6000 ; Set Z probe type to switch and the dive height + speeds
;G31 P600 X0 Y0 Z2.5 ; Set Z probe trigger value, offset and trigger height
;M557 X15:200 Y15:169 S20 ; Define mesh grid
; Heaters
M305 P0 T100000 B4138 C0 R4700 ; Set thermistor + ADC parameters for heater 0
M143 H0 S120 ; Set temperature limit for heater 0 to 120C
M305 P1 T100000 B4725 C7.060000e-8 R4700 ; Set thermistor + ADC parameters for heater 1
M143 H1 S280 ; Set temperature limit for heater 1 to 280C
; Fans
M106 P0 S0 I0 F500 H-1 ; Set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off
M106 P1 S1 I0 F500 H1 T45 ; Set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on
M106 P2 S1 I0 F500 H1 T45 ; Set fan 2 value, PWM signal inversion and frequency. Thermostatic control is turned on
; Tools
M563 P0 D0 H1 ; Define tool 0
G10 P0 X0 Y0 Z0 ; Set tool 0 axis offsets
G10 P0 R0 S0 ; Set initial tool 0 active and standby temperatures to 0C
; Automatic saving after power loss is not enabled
; Custom settings are not configured
dla przypomnienia wczesniej bylo tak: